Review



human opn immunoassay  (R&D Systems)


Bioz Verified Symbol R&D Systems is a verified supplier
Bioz Manufacturer Symbol R&D Systems manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 95

    Structured Review

    R&D Systems human opn immunoassay
    Human Opn Immunoassay, supplied by R&D Systems, used in various techniques. Bioz Stars score: 95/100, based on 160 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/quantikine+human+opn+immunoassay/Human+Osteopontin+(OPN)+Quantikine+ELISA+Kit/10__4103_slash_ijh__ijh_93_24-45-17-23
    Average 95 stars, based on 160 article reviews
    human opn immunoassay - by Bioz Stars, 2026-09
    95/100 stars

    Images

    Related Articles

    Cell Culture:

    Article Title: Beclin1-induced autophagy abrogates radioresistance of lung cancer cells by suppressing osteopontin.
    Article Snippet: .. OPN levels from cultured medium were determined by quantikine human OPN immunoassay from R&D Systems (Minneapolis, MN), and the results were read on a Microplate Reader (Bio-Rad Laboratory) at OD 450 nm. ..

    Article Title: The O‑glycosylation mutant osteopontin alters lung cancer cell growth and migration in vitro and in vivo.
    Article Snippet: .. OPN levels from a cultured medium were then determined via Quantikine Human OPN Immunoassay from R&D Systems (Minneapolis, MN, USA). .. The results were read on a microplate reader from Bio-Rad at 450 nm OD.

    Enzyme-linked Immunosorbent Assay:

    Article Title: Osteopontin as novel biomarker for reversibility of pressure overload induced left ventricular hypertrophy.
    Article Snippet: .. OPN was measured using the Quantikine Human OPN immunoassay (R&D Systems, MN, USA) which employs the quantitative sandwich enzyme immunoassay technique. ..

    Article Title: Plasma osteopontin levels are associated with disease activity in the patients with multiple sclerosis and neuromyelitis optica.
    Article Snippet: Contents lists available at ScienceDirect Journal of Neuroimmunology j ourna l homepage: www.e lsev ie r .com/ locate / jneuro im Short communication Plasma osteopontin levels are associated with disease activity in the patients with multiple sclerosis and neuromyelitis optica Yuko Shimizu a,⁎, Kohei Ota b, Ryotaro Ikeguchi a, Sachiko Kubo a, Chiaki Kabasawa a, Shinichiro Uchiyama a a Department of Neurology, Tokyo Women's Medical University, School of Medicine, Tokyo, Japan b Faculty of Science, Tokyo University of Science, Tokyo, Japan ⁎ Corresponding author at: Department of Neurolo University School of Medicine, 8-1 Kawadacho, Sh Japan.. Tel.. : +81 3 3353 8111x39232; fax: +81 3 52 E-mail address: yshimizu@nij.twmu.ac.jp (Y. Shimizu) 0165-5728/$ – see front matter © 2013 Elsevier B.V. All r http://dx.doi.org/10.1016/j.jneuroim.2013.07.005 a b s t r a c t a r t i c l e i n f o Article history: Received 29 April 2013 Received in revised form 5 July 2013 Accepted 8 July 2013 Keywords: Plasma osteopontin Multiple sclerosis Neuromyelitis optica Disease activity Disease progression Osteopontin (OPN) up-regulates pro-inflammatory cytokines from both T helper type 1 and T helper type 17 cell pathways.Wemeasured plasma OPN levels in Japanesemultiple sclerosis (MS) and neuromyelitis optica (NMO) patients to investigate its value as a potential biomarker of disease activity.

    Article Title: Osteopontin predicts clinical outcome in patients after treatment of severe aortic stenosis with transcatheter aortic valve implantation (TAVI)
    Article Snippet: .. OPN was measured using the Quantikine Human OPN immunoassay from R&D Systems (Minneapolis, USA) that employs the quantitative sandwich enzyme immunoassay technique. ..

    Clinical Proteomics:

    Article Title: Plasma osteopontin levels are associated with disease activity in the patients with multiple sclerosis and neuromyelitis optica.
    Article Snippet: Contents lists available at ScienceDirect Journal of Neuroimmunology j ourna l homepage: www.e lsev ie r .com/ locate / jneuro im Short communication Plasma osteopontin levels are associated with disease activity in the patients with multiple sclerosis and neuromyelitis optica Yuko Shimizu a,⁎, Kohei Ota b, Ryotaro Ikeguchi a, Sachiko Kubo a, Chiaki Kabasawa a, Shinichiro Uchiyama a a Department of Neurology, Tokyo Women's Medical University, School of Medicine, Tokyo, Japan b Faculty of Science, Tokyo University of Science, Tokyo, Japan ⁎ Corresponding author at: Department of Neurolo University School of Medicine, 8-1 Kawadacho, Sh Japan.. Tel.. : +81 3 3353 8111x39232; fax: +81 3 52 E-mail address: yshimizu@nij.twmu.ac.jp (Y. Shimizu) 0165-5728/$ – see front matter © 2013 Elsevier B.V. All r http://dx.doi.org/10.1016/j.jneuroim.2013.07.005 a b s t r a c t a r t i c l e i n f o Article history: Received 29 April 2013 Received in revised form 5 July 2013 Accepted 8 July 2013 Keywords: Plasma osteopontin Multiple sclerosis Neuromyelitis optica Disease activity Disease progression Osteopontin (OPN) up-regulates pro-inflammatory cytokines from both T helper type 1 and T helper type 17 cell pathways.Wemeasured plasma OPN levels in Japanesemultiple sclerosis (MS) and neuromyelitis optica (NMO) patients to investigate its value as a potential biomarker of disease activity.

    Concentration Assay:

    Article Title: Plasma osteopontin levels are associated with disease activity in the patients with multiple sclerosis and neuromyelitis optica.
    Article Snippet: Contents lists available at ScienceDirect Journal of Neuroimmunology j ourna l homepage: www.e lsev ie r .com/ locate / jneuro im Short communication Plasma osteopontin levels are associated with disease activity in the patients with multiple sclerosis and neuromyelitis optica Yuko Shimizu a,⁎, Kohei Ota b, Ryotaro Ikeguchi a, Sachiko Kubo a, Chiaki Kabasawa a, Shinichiro Uchiyama a a Department of Neurology, Tokyo Women's Medical University, School of Medicine, Tokyo, Japan b Faculty of Science, Tokyo University of Science, Tokyo, Japan ⁎ Corresponding author at: Department of Neurolo University School of Medicine, 8-1 Kawadacho, Sh Japan.. Tel.. : +81 3 3353 8111x39232; fax: +81 3 52 E-mail address: yshimizu@nij.twmu.ac.jp (Y. Shimizu) 0165-5728/$ – see front matter © 2013 Elsevier B.V. All r http://dx.doi.org/10.1016/j.jneuroim.2013.07.005 a b s t r a c t a r t i c l e i n f o Article history: Received 29 April 2013 Received in revised form 5 July 2013 Accepted 8 July 2013 Keywords: Plasma osteopontin Multiple sclerosis Neuromyelitis optica Disease activity Disease progression Osteopontin (OPN) up-regulates pro-inflammatory cytokines from both T helper type 1 and T helper type 17 cell pathways.Wemeasured plasma OPN levels in Japanesemultiple sclerosis (MS) and neuromyelitis optica (NMO) patients to investigate its value as a potential biomarker of disease activity.



    Similar Products

    95
    R&D Systems human opn immunoassay
    Human Opn Immunoassay, supplied by R&D Systems, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/quantikine+human+opn+immunoassay/Human+Osteopontin+(OPN)+Quantikine+ELISA+Kit/10__4103_slash_ijh__ijh_93_24-45-17-23
    Average 95 stars, based on 1 article reviews
    human opn immunoassay - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    95
    R&D Systems quantikine elisa human osteopontin immunoassay kit
    Quantikine Elisa Human Osteopontin Immunoassay Kit, supplied by R&D Systems, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/quantikine+human+opn+immunoassay/Human+Osteopontin+(OPN)+Quantikine+ELISA+Kit/pm37523079-39-11-17
    Average 95 stars, based on 1 article reviews
    quantikine elisa human osteopontin immunoassay kit - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    95
    R&D Systems human osteopontin immunoassay kit
    Concentration of <t>osteopontin</t> in plasma of LAM patients and normal volunteers. A, concentration of osteopontin (OPN) in plasma of 40 LAM patients who had not undergone lung transplantation compared with that of 35 healthy female volunteers. There was a significant difference in the levels of osteopontin, with a P value of 3.6 × 10−5. B, correlation between the levels of osteopontin (ng/mL) with the initial FEV1 and initial DLCO. C, correlation between the levels of osteopontin (ng/mL) with the rate of FEV1 decline and rate of DLCO decline.
    Human Osteopontin Immunoassay Kit, supplied by R&D Systems, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/quantikine+human+opn+immunoassay/Human+Osteopontin+(OPN)+Quantikine+ELISA+Kit/pmc10068840-144-15-20
    Average 95 stars, based on 1 article reviews
    human osteopontin immunoassay kit - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    95
    R&D Systems quantitative sandwich enzyme immunoassay technique
    Concentration of <t>osteopontin</t> in plasma of LAM patients and normal volunteers. A, concentration of osteopontin (OPN) in plasma of 40 LAM patients who had not undergone lung transplantation compared with that of 35 healthy female volunteers. There was a significant difference in the levels of osteopontin, with a P value of 3.6 × 10−5. B, correlation between the levels of osteopontin (ng/mL) with the initial FEV1 and initial DLCO. C, correlation between the levels of osteopontin (ng/mL) with the rate of FEV1 decline and rate of DLCO decline.
    Quantitative Sandwich Enzyme Immunoassay Technique, supplied by R&D Systems, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/quantikine+human+opn+immunoassay/Human+Osteopontin+(OPN)+Quantikine+ELISA+Kit/pmc09015153-226-17-30
    Average 95 stars, based on 1 article reviews
    quantitative sandwich enzyme immunoassay technique - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    95
    R&D Systems quantikine human osteopontin immunoassay kit
    Primer sequences, reaction conditions, and product size for RT-PCR
    Quantikine Human Osteopontin Immunoassay Kit, supplied by R&D Systems, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/quantikine+human+opn+immunoassay/Human+Osteopontin+(OPN)+Quantikine+ELISA+Kit/pmc08721409-58-13-18
    Average 95 stars, based on 1 article reviews
    quantikine human osteopontin immunoassay kit - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    92
    R&D Systems quantikine human opn immunoassay
    Primer sequences, reaction conditions, and product size for RT-PCR
    Quantikine Human Opn Immunoassay, supplied by R&D Systems, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/quantikine+human+opn+immunoassay/Quantikine+Immunoassay+Control+Set+960+for+Human+Osteopontin/pm32462909-50-5-9
    Average 92 stars, based on 1 article reviews
    quantikine human opn immunoassay - by Bioz Stars, 2026-09
    92/100 stars
      Buy from Supplier

    95
    R&D Systems quantikine r human osteopontin opn immunoassay
    Primer sequences, reaction conditions, and product size for RT-PCR
    Quantikine R Human Osteopontin Opn Immunoassay, supplied by R&D Systems, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/quantikine+human+opn+immunoassay/Human+Osteopontin+(OPN)+Quantikine+ELISA+Kit/pm32198577-47-16-22
    Average 95 stars, based on 1 article reviews
    quantikine r human osteopontin opn immunoassay - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    95
    R&D Systems immunoassay
    Primer sequences, reaction conditions, and product size for RT-PCR
    Immunoassay, supplied by R&D Systems, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/quantikine+human+opn+immunoassay/Human+Osteopontin+(OPN)+Quantikine+ELISA+Kit/pm29122516-67-47-48
    Average 95 stars, based on 1 article reviews
    immunoassay - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    95
    R&D Systems immunosorbent assay elisa kit quantikine human osteopontin immunoassay
    Primer sequences, reaction conditions, and product size for RT-PCR
    Immunosorbent Assay Elisa Kit Quantikine Human Osteopontin Immunoassay, supplied by R&D Systems, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/quantikine+human+opn+immunoassay/Human+Osteopontin+(OPN)+Quantikine+ELISA+Kit/pmc05815337-81-9-17
    Average 95 stars, based on 1 article reviews
    immunosorbent assay elisa kit quantikine human osteopontin immunoassay - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    Image Search Results


    Concentration of osteopontin in plasma of LAM patients and normal volunteers. A, concentration of osteopontin (OPN) in plasma of 40 LAM patients who had not undergone lung transplantation compared with that of 35 healthy female volunteers. There was a significant difference in the levels of osteopontin, with a P value of 3.6 × 10−5. B, correlation between the levels of osteopontin (ng/mL) with the initial FEV1 and initial DLCO. C, correlation between the levels of osteopontin (ng/mL) with the rate of FEV1 decline and rate of DLCO decline.

    Journal: Cancer research

    Article Title: TSC2 Loss in Lymphangioleiomyomatosis Cells Correlated with Expression of CD44v6, a Molecular Determinant of Metastasis

    doi: 10.1158/0008-5472.CAN-07-1356

    Figure Lengend Snippet: Concentration of osteopontin in plasma of LAM patients and normal volunteers. A, concentration of osteopontin (OPN) in plasma of 40 LAM patients who had not undergone lung transplantation compared with that of 35 healthy female volunteers. There was a significant difference in the levels of osteopontin, with a P value of 3.6 × 10−5. B, correlation between the levels of osteopontin (ng/mL) with the initial FEV1 and initial DLCO. C, correlation between the levels of osteopontin (ng/mL) with the rate of FEV1 decline and rate of DLCO decline.

    Article Snippet: Osteopontin was quantified by ELISA in plasma from LAM patients and normal volunteers using the Human Osteopontin Immunoassay kit from R&D Systems.

    Techniques: Concentration Assay, Clinical Proteomics, Transplantation Assay

    Primer sequences, reaction conditions, and product size for RT-PCR

    Journal: Journal of the Korean Association of Oral and Maxillofacial Surgeons

    Article Title: Effects of the combination of bone morphogenetic protein-2 and nano-hydroxyapatite on the osseointegration of dental implants

    doi: 10.5125/jkaoms.2021.47.6.454

    Figure Lengend Snippet: Primer sequences, reaction conditions, and product size for RT-PCR

    Article Snippet: The concentration of OPN protein in the culture medium was measured using a Quantikine Human Osteopontin Immunoassay kit (R&D Systems, Minneapolis, MN, USA).

    Techniques: Sequencing

    Bone marrow-derived mesenchymal stem cell (BM-MSC) differentiation on differently treated titanium disks. A. Flow cytometry of typical CD markers present on BM-MSCs cultured on the Col-, Col/nHAp-, or Col/nHAp/BMP-2-coated titanium disks. CD73+, CD90+, and CD105+ cells were observed prior to differentiation. Reduction in mesenchymal CD73+, CD90+, and CD105+ cells was observed in the Col/nHAp/BMP-2 group. B. Biochemical assays for alkaline phosphatase (ALP) activity and intracellular glycosaminoglycan (GAG) and osteopontin expression in BM-MSCs. Cells on Col/nHAp/BMP-2 exhibited the highest expression. C. mRNA expression of different osteoblastic markers in BM-MSC. The highest expression was observed for type III collagen (Col III), osteocalcin, and osteoprotegerin in cells grown on Col/nHAp/BMP-2. The levels of type I collagen (Col I), osteopontin, osteonectin, and BMP-2 expression were higher in BM-MSCs on Col/nHAp and Col/nHAp/BMP-2 than in those with Col enrichment. (Col: collagen, nHAp: nano-hydroxyapatite, BMP-2: bone morphogenetic protein-2)

    Journal: Journal of the Korean Association of Oral and Maxillofacial Surgeons

    Article Title: Effects of the combination of bone morphogenetic protein-2 and nano-hydroxyapatite on the osseointegration of dental implants

    doi: 10.5125/jkaoms.2021.47.6.454

    Figure Lengend Snippet: Bone marrow-derived mesenchymal stem cell (BM-MSC) differentiation on differently treated titanium disks. A. Flow cytometry of typical CD markers present on BM-MSCs cultured on the Col-, Col/nHAp-, or Col/nHAp/BMP-2-coated titanium disks. CD73+, CD90+, and CD105+ cells were observed prior to differentiation. Reduction in mesenchymal CD73+, CD90+, and CD105+ cells was observed in the Col/nHAp/BMP-2 group. B. Biochemical assays for alkaline phosphatase (ALP) activity and intracellular glycosaminoglycan (GAG) and osteopontin expression in BM-MSCs. Cells on Col/nHAp/BMP-2 exhibited the highest expression. C. mRNA expression of different osteoblastic markers in BM-MSC. The highest expression was observed for type III collagen (Col III), osteocalcin, and osteoprotegerin in cells grown on Col/nHAp/BMP-2. The levels of type I collagen (Col I), osteopontin, osteonectin, and BMP-2 expression were higher in BM-MSCs on Col/nHAp and Col/nHAp/BMP-2 than in those with Col enrichment. (Col: collagen, nHAp: nano-hydroxyapatite, BMP-2: bone morphogenetic protein-2)

    Article Snippet: The concentration of OPN protein in the culture medium was measured using a Quantikine Human Osteopontin Immunoassay kit (R&D Systems, Minneapolis, MN, USA).

    Techniques: Derivative Assay, Flow Cytometry, Cell Culture, Activity Assay, Expressing